SRW-TEC-004-10: Segmental Retaining Wall Design
Concrete Masonry & Hardscapes Association (CMHA, formerly NCMA and ICPI)
Open the source- Consulted
- October 10, 2026
- Region
- US
- Language
- en
Cited by
Glossary terms
What we take from it
- CMHA recommends an engineered design above 1.2 m total height where the local code is silent.
- CMHA calls for at least 300 mm of drainage stone behind the units, a drain of at least 75 mm and outlets at most 15 m apart.
- CMHA sets the minimum length at the greater of 0.6 H and 1.2 m and a maximum vertical spacing between layers.
- CMHA requires the wall drain to discharge at outlets.
- CMHA calls for at least 300 mm of drainage stone behind the units.
- CMHA spaces drain outlets no more than 15 m apart.
- CMHA sets the minimum geogrid length at the greater of 0.6 H and 1.2 m.
- CMHA recommends an engineered design above 1.2 m total height if the local code is silent.
- Drainage, geogrid length and the 1.2 m threshold.